Measure - Control - Position

P40 Two-axis-version
  • easy handling
  • integratet diagnosis system
  • digital outputs or relay outputs possible
  • option PID analog output available

    Applications

    • Woodworking machines
    • Band saws
    • Grinding machines
    • Shears
    • Bedstops
    • Press breaks

      ... and many further applications

      Standard functions

      • Adjustable positioning output signals
      • Display of required and actual position
      • Absolute or incremental positioning
      • Reference or datuming sequence possibility
      • mm/inch switch
      • Pulse multiplication factor
      • Tolerance windows
      • Software limit
      • Blacklash compensation
      • Up to 500 address lines programmable
      • Offset calculation
      • Pulse monitoring
      • Quantity counter
      • Hand mode
      • 20 offset values
      • Bedstop controller
      • Actual value memory

      Technical specifications

      Display

      LCD point matrix with backround lighting

      Connection value

      24 VDC, max. 200 mA
      24 VAC, max. 20 VA
      with uploaded outputs and not tightened relays

      Puls generator supply

      24 VCD, max. 130 mA

      Connection technology

      Plug connector

      System accuracy

      +/- 1 Increment

      Actual value memory

      10 years (EE-Prom)

      Metering frequenzy

      100 KHz

      Operating temperature

      0 - 50 °C

      Storage temperature

      0 - 70 °C

      Humidity

      non condensing, max. 80 %

      Housing

      Aluminium, frame construction

      Housing dimensions

      144 x 144 mm

      Outbreak measured

      138 x 138 mm

      Installation depth

      max. 75 mm
      max. 83 mm with RIA - connections
      max. 110 mm with D-Sub connections

      Keyboard

      Foil, short-stroke-grope

      Protection class

      IP 43 (in the installation)

      Inputs

      Measuring systems

      1 measuring system (standard)

      Input signals statically

      PNP (Option - EN:NPN), 300 ms minimum pulse time/ PIN, max. 10 mA/ Input current/ Pin Start, Stop, rReference, chains minus, chains plus,
      Departure, fixed position, number of items adding/subtracting, Eend position minus, end position plus, System RESET

      Outputs

      Output signals

      Push / pull, limited short circuit proof
      max. 10 mA output current, integrated catch diodes (at Option-R floating relays as normally open contact, max. 5 A bei 230 VAC resp. max.2 A at 24 VDC)

      Analog

      +/- 10V for DC drives
      2-speed controls for AC engines, unipolar control incl. Direction exits,
      Drive signals, Position reached, automatic controller release, number of items reached, reference driven runs, mode of operation hand, mode of operation single

      Download

      English

      Operation Manual

       P40

      German

      Operation Manual

       P40

      French

      Operation manual

       P40