Measure - Control - Position

LCD-Display | 7 decades (digit height 14 mm) |
Measuring units | mm, m, inch oder "°" |
Perspective | 12 o'clock |
Power supply | 1.5 V or 3.0 V (+24 V on request) |
Power consumption | < 1 mA at 1.5 V |
Battery life | 1 ... 3 years (depending on the battery-type) |
Operating temperature | 0 °C ... + 50 °C |
Storage temperature | -20 °C ... + 80 °C |
Humidity | max. 80 %, non-condensing |
Velocity | max. 4 m/s |
Housing | Norm panel housing, ABS plastic, black |
Housing dimensions | W x H = 96 x 72 mm |
Installation depth | 30 mm (depending on version) |
Panel cut out | W x H = 93 x 67 mm |
Protection class front | IP 54 (when installed with sealing) |
Protection class back | IP 40 |
| |
Pole length | 2.5 mm |
Senosr cable length | 0.1 ... 2.0 m |
Senosr cable | Drag-chain suitable, 6-wires, twisted pairs and double shielded |
Housing | Zinc die cast |
Protection class | IP 67 |
Mounting position | User defined |
Bending radius | min. 60 mm |
Distance sensor/tape | max. 1.0 mm (without cover band) |
Operating temperature | 0 °C ... +50 °C |
Storage temperature | -20 °C ... +80 °C |
Influence of external magnetic fields | External magnetic fields > 1 mT, which directly impinge upon the sensor can affect the system accuracy |
| |
Coding | Incremental, single track |
Pole length | 2.5 mm |
Operating temperature | 0 °C ... +50 °C |
Storage temperature | short-term: -10 °C...+60 °C, medium-term: 0 °C...+40 °C, long-term: +18 °C |
Relative humidity | max. 95 %, non-condensing |
Accuracy at 20 °C in mm | +/- (0.025 + 0.02 x L) L = measuring length in meter |
Thermal expansion | ΔL[m] = L[m] x α[1/K] x Δ[K] |
Linear expansion coefficient | α = 16 x 10-6 1/K |
Bendign radius | min. 150 mm |
Available lenths | 32 m (up to 70 m on request) |
Weight of the magnetic tape | ca. 62 g/m (incl. adhesive tape + protective tape) |
Weight of cover band | ca. 19 g/m (incl. adhesive tape + protective tape) |
Influence of external magnetic fields | External magnetic fields are not allowed to exceed 64 mT (640 Oe; 52 kA/m) at the magnetic tape surface, because it can destroy and damage the magnetic tape code. |
Protection class | IP 67 |