Measure - Control - Position

Z57
  • easy handling
  • external set/reset/inhibit inputs
  • digital brightness control
  • extensive programmable output performance
  • potential free output relays (changeovers)

Technical specifications

Nominal voltage AC

230 V or 115 V

Nominal voltage DC

24 V

Allowed tolerance of voltage

+/- 10%

Power consumption

230 VAC = 15 VA / 24 VDC = 12 W

Housing

panel housing, anodized Aluminium

Protection class Housing / Connections

IP40 / IP00

Connection

plugable screw terminals up to 2.5 mm2

Operation temperature

0...+50 °C

Supply / encoder

24 VDC / 200 mA, short circuit proof

Consumption at 24 V DC
signal input
external input

10 mA
10 mA

Input frequency
signal input max.
external input max.

20 KHz (100 KHz at Option M)
60 Hz

Relay outputs

2 (1 at SN011) changeovers 250 VAC / 3 A

Displays

6 digit LED, red, 8 mm high, with sign 1 x LED red (status of relays)

Panel cut out

W x D = 67 x 93 mm

Download

English

Flyer

 Flyer Z57

 

Operation manual

 Z57

German

Flyer

 Flyer Z57

 

Operation manual

 Z57