Measure - Control - Position

Display | 7 digits with sign +/- |
Power supply | 24 VDC, +/- 10 % |
Consumption without measuring system | max. 50 mA |
Operating temperature | 0° to + 50° C |
Supply of measuring system | stabilized 24 VDC +/- 10 % |
Counting frequency of measuring system | 20 KHz PNP, at 24 V level (more on request) 100 KHz at inverted TTL- signals |
Index input (Z) | edge triggered |
Input signals | PNP (active high), pulse time min. 300 msec |
Measuring system inputs | PNP (active high) |
External inputs (Option E) | PNP, positive Logic |
Power down memory | NOVRAM (service life approx. 10 years) |
Housing | black Aluminium panel- or built on housing |
Dimensions of housing | built on:width 107mm x height 76mm |
install depth (panel version) | panel 68mm, built on 170 mm (inclusive connectors) |
Depth (built on version) | 170 mm inclusive connectors |
Cut out panel | wide 92mm x height 96 mm |
Protection class | in mounted status IP40 |