Measure - Control - Position

Z60
  • graphic display 120 x 80 pixels
  • signs
  • bitmaps
  • 3 digital external inputs
  • 1 analog input 0 ... 10 VDC or 4 ... 20 mA (option)
  • 2 outputs open drain
  • 2 relay outputs
  • 1 analog output 0 ... 10 VDC and 1 analog output 4 ... 20 mA (option)
  • easy mounting
  • inch-mode
  • tool-offset function
  • switch-over between incremental and absolute measuring
  • actual value memory
  • adjustable reference value
  • adjustable pulse scaling factor / edge triggering
  • operation modes up / down or differential counter

Technical specifications

Input supply voltage

24 VDC +/- 20 %

Consumption

max. 120 mA (without measuring system)

Encoder supply

5 VDC or 24 VDC

Max. consumption of the measuring system

300 mA

Display

LCD, 120 x 80 pixel

System accurycy

+/- 1 digit

Operation temperature

0 ... +50 °C

Storage temperature

-40 ... +70 °C

Humidity

not condensing, max. 80 %

Protection class

IP43 (front side)

Relay outputs

potential free closer relays 24 VDC / max. 1 A

Inputs

max. input mA PNP (active high), switch voltage 24 VDC

Memory of actual value

FRAM

Housing

Input housing

aluminium

Dimensions

96 x 72 mm

Front panel outbreak

93 x 67 mm

Installation depth

33 mm (without connector)