Measure - Control - Position

Mechanical Data | |
Measuring principle | incremental |
Repeat accuracy | +/- 1 increment |
System accuracy in µm at 20 °C | +/- (1000 + 20 x L) |
Distance from sensor to magnetic tape | max. 10 mm |
Pole pitch | 16 mm |
Material sensor housing | zinc die casting |
Housing dimensions | L x B x H = 30 x 10 x 15 mm |
Required magnetic tape | MB20-160-10-1-R |
Measuring length | theoretically unlimited |
Cable connection | D-SUB connector 9-pin |
Weight | sensor + D-SUB connector: about 40 g without cablel |
Ambient Conditions | |
Storage temperature | -25 ... +85 °C |
Operation temperature | -10 ... +70 °C (-25 ... +85 °C on request) |
Protection class | IP67 |
Electrical Data | |
Power supply | 10 - 30 VDC / 5 VDC |
Periodic and random deviation | 10 - 30 V: < 10% |
Current consumption | 10 - 30 VDC: max. 150 mA |
Output signals | A, A', B, B', Z, Z' |
Output level | 10 ... 30 V-HTL / 5 V-TTL |
Resolution(4 edge triggering) | 1 mm |
Index pulsw | 16 mm periodical |
Max. output frequency per channel | 10 kHz |
Movement speed | max. 20 m/s |
Sensor cable | 1.5 m standard cable length, others on request, drag chain compliant |