Measure - Control - Position

EMAX / EMAX2
  • Absolute measuring
  • Resolution 0.01 mm
  • No calibration necessary - changes of position are also recognized in zero-current period
  • EMAX2 additional with LED and SSI error-bit in case of too large distance sensor-tape
  • Measuring length up to 20 m (EMAX2)
  • Incremental square- or sine-cosine signals for dynamical movement control (optional EMAX2)

 

        picture EMAX2

Technical Specifications EMAX

Connection voltage

10...30 VDC +/- 10 % residual ripple < 5 %

Current consumption

max. 150 mA

Signal level

Interface dependent

Repeat accuracy

+/- 0.01 mm

System accuracy in

µ at 20 °C

+/- (150 + 20 x L)
L = measured length in meters

Resolution

0.01 mm

Operation speed

4 m/sec.

RS232 / RS422

data transmission

9600 Bit/s, 8 Datenbits,
1 Stopbit, no parity

Measured length

max. 10 m

Distance / sensor

max. 0.8 mm

Operating temperature

-10 ...+70 °C (-25 ...+85 °C on inquiry)

Storage temperature

-25 ...+85 °C

Air humidity

non-condensing max. 80 %

Protection class

IP 54

Option V

IP 67

Cable

Cable lenghts

max. 30.0 m

min. bending radius

60 mm

 

 

Technical Specifications EMAX2

Mechanical Data

Measuring principle

absolute

Repeating accuracy

+/- 1 increment

System accuracy in µm 
at 20 °C         

+/- (150 + 20 x L)   -   type designation 010
+/- (50 + 20 x L)     -   type designation F10
L= effective measuring length in meter

Distance sensor - tape

max. 1.5 mm,
2 mm with limited measuring accuracy

Basic pole pitch

5 mm

Material sensor housing

zinc die casting

Housing dimensions

L x W x H: 75 x 24 x 26 mm 
with guided carriage: L x W x H: 100 x 34 x 48 mm

Magnetic tape

AB20-50-10-2-R-11 (measuring length 10 m)
AB20-50-10-2-R-12 (measuring length 20 m)

Measuring length

up to 10 m (EMAX2)
up to 20 m (EMAL)

Cable connection

open cable end

Weight

ca. 100 g (without cable)
cable: ca. 60 g per meter

Ambient Conditions                

Operation temperature

-10 ... +70 °C,
-25 ... +85 °C on request

Storage temperture

-25 ... +85 °C

Protection class

IP40 (standard)
IP65 (option V)

Electrical Data

Power supply

10 ... 30 VDC +/- 10 %

Periodic and random deviation

10 ... 30 V: < 10 %

Current consumption

max. 150 mA

Interfaces

SSI-Interface, CANopen (DS406), RS422, addressable RS422

Resolution

0.01 mm

Max. output frequency

4 m/s

Sensor cable

1.5 m standard cable length,
others on request,
drag chain compliant

 

 

Download

English

Flyer

 Flyer EMAX

 

Operation Manual

 EMAX

 EMAX2

 

Software

 EDS-File (for CAN-Interface)

 GSD-File (for Profibus-Interface)

German

Flyer

 Flyer EMAX

 

Operation Manual

 EMAX

 EMAX2

   

Software

 EDS-file (for CAN-interface)

 GSD-file (for Profibus-interface)