Measure - Control - Position

picture EMAX2
Connection voltage | 10...30 VDC +/- 10 % residual ripple < 5 % |
Current consumption | max. 150 mA |
Signal level | Interface dependent |
Repeat accuracy | +/- 0.01 mm |
System accuracy in µ at 20 °C | +/- (150 + 20 x L) |
Resolution | 0.01 mm |
Operation speed | 4 m/sec. |
RS232 / RS422 data transmission | 9600 Bit/s, 8 Datenbits, |
Measured length | max. 10 m |
Distance / sensor | max. 0.8 mm |
Operating temperature | -10 ...+70 °C (-25 ...+85 °C on inquiry) |
Storage temperature | -25 ...+85 °C |
Air humidity | non-condensing max. 80 % |
Protection class | IP 54 |
Option V | IP 67 |
Cable | |
Cable lenghts | max. 30.0 m |
min. bending radius | 60 mm |
Mechanical Data | |
Measuring principle | absolute |
Repeating accuracy | +/- 1 increment |
System accuracy in µm | +/- (150 + 20 x L) - type designation 010 |
Distance sensor - tape | max. 1.5 mm, |
Basic pole pitch | 5 mm |
Material sensor housing | zinc die casting |
Housing dimensions | L x W x H: 75 x 24 x 26 mm |
Magnetic tape | AB20-50-10-2-R-11 (measuring length 10 m) |
Measuring length | up to 10 m (EMAX2) |
Cable connection | open cable end |
Weight | ca. 100 g (without cable) |
Ambient Conditions | |
Operation temperature | -10 ... +70 °C, |
Storage temperture | -25 ... +85 °C |
Protection class | IP40 (standard) |
Electrical Data | |
Power supply | 10 ... 30 VDC +/- 10 % |
Periodic and random deviation | 10 ... 30 V: < 10 % |
Current consumption | max. 150 mA |
Interfaces | SSI-Interface, CANopen (DS406), RS422, addressable RS422 |
Resolution | 0.01 mm |
Max. output frequency | 4 m/s |
Sensor cable | 1.5 m standard cable length, |
Flyer
Operation Manual
Software
Flyer
Operation Manual
Software