Measure - Control - Position

Measuring principle | Incremental | |
Signal output | Speed proportional | |
Resolution (4 edge-triggered) | 0.001 mm | |
Repeating accuracy | +/- 0.001 mm | |
Accuracy of the system in µm at 20 °C | +/- (20 + 20 x L) (L = measuring length in meters) | |
Max. permitted distance to the tape | 0.8 mm | |
Power supply | 5 VDC oder 10... 30 VDC | |
| 5 VDC: +/- 2,5 %, remaining ripple < 50 mV | |
Consumption | 5 VDC: max. 200 mA | |
Translator circuit intern/extern | intern | |
Output levels | 5 VDC- TTL Line Driver oder 10… 30 VDC- HTL | |
Output channels | A, A’, B, B’, Z, Z’ | |
Output characteristics | Push/Pull, durable short circuit proof | |
Max. output frequency per channel | TTL: 100 KHz at 0.4 m/s resp. 500 KHz at 2,0 m/s | |
Output current per channel | 20 mA | |
Max. operating speed | 2,0 m/s | |
Index pulses | Periodic output of channels Z and Z´ | |
Maximum cable length | 5 VDC / 5 V-TTL = 10 m | |
Min. bending radius of sensor cable | 60 mm | |
Operation temperature | -10 ... +70 °C (-25 ... +85 °C on inquiry) | |
Storage temperature | -25 ... +85 °C | |
Humidity | 95 %, non-condensing | |
Housing | Zinc die cast | |
Protection class | IP67 | |
Dimensions | 30 mm x 12.5 mm x 25 mm | |
Mounting position | Horizontal or vertical (Option L) | |
Mechanical guidance | None |