Measure - Control - Position
Autoreferencing, absolute, magnetic length measuring system
Mechanical Data | |
Measuring principle | autoreferencing-absolute |
Repeat accuracy | +/- 1 mm |
System accuracy | +/- (1250 + 20 x L) |
Distance between sensor | 1,8 mm |
Basic pole pitch | 4 mm |
Sensor housing material | ABS-plastic material |
Sensor housing dimensions | L x W x H = 50 x 12 x 25 mm |
Required magnetic tape | AB20-40-10-1R-D-18 |
Max. measuring length | 1000 m |
Cable connection | open cable ends |
Weight | ca. 40 g without cable |
Ambient temperatures | |
Storage temperature | -25... +85 °C |
Operating temperature | -10... +70 °C |
Protection class | IP67 |
Electrical Data | |
Power supply | 10... 30 VDC +/- 10% |
Random and periodic | 1 - 30V: < 10% |
Current consumption | max. 150 mA |
Interfaces | CANopen (DS406) |
Resolution | 1 mm |
Max. travelling speed | 4 m/s |
Sensor cable | 1,5 m standard cable length, |