Measure - Control - Position

Mechanical Data | |
Measuring principle | absolute |
Repeat accuracy | +/- 1 mm |
System accuracy | +/- (1000 µm + 20 µm x L) |
Distance between sensor | 2 mm |
Basic pole pitch | 4 mm |
Sensor housing material | Aluminium |
Sensor housing dimensions | L < 150 mm (to be defined) |
Necessary magnetic tape | AB20-40-08-1-R-D-17A |
Max. measuring length | 40 m |
Cable connection | open cable end |
Weight | ca. 140 g without cable |
Ambient temperature | |
Storage temperature | -25 ... +85 °C |
Operation temperature | -10 ... +70 °C |
Protection class | IP50 |
Electrical Data | |
Power supply | 10 - 30 VDC |
Periodic and | 10 - 30 V: < 10% |
Current consumption | max. 0,2 A |
Interfaces | RS422, SSI (others on request) |
Resolution | 0,5 mm |
Max. travel speed | max. 2 m/s |
Sensor cable | 3 m standard cable length, |