Measure - Control - Position

Mechanical Data | |
Measuring principle | absolute |
Repeat accuracy | +/- 1 mm |
System accuracy in µm at 20 °C | +/- (1000 µm + 20 µm x L) |
Distance between sensor | 4 mm |
Basic pole pitch | 8 mm |
Sensor housing material | Aluminium |
Sensor housing dimensions | L x W x H = 355 x 85 x 48 mm |
Necessary magnetic tape | AB20-80-10-1-R-D-15-BK80 |
Max. measuring length | 260 m |
Cable connection | open cable ends |
Weight | ca. 900 g without cable |
Ambient temperature | |
Storage temperature | -25 ... +85 °C |
Operation temperature | -10 ... +70 °C |
Protection class | IP54 |
Electrical Data | |
Power supply | 10 - 30 VDC |
Periodic and random deviation | 10 - 30 V: < 10% |
Current consumption | max. 0,6 A |
Interfaces | CANopen safety (DS406, DS417), RS485 |
Resolution | 1 mm (others on request) |
Speed | max. 6 m/s |
Sensor cable | 3 m standard cable length, |