Measure - Control - Position

LIMAX33 RED
  • Redundant double sensor with integrated monitoring system
  • Tested by TÜV according to SIL 3 (TÜV: Technical Inspection Authority)
  • Absolute position is always and directly available - no referencing even after long power cuts
  • Available interfaces: CANopen safety (DS406, DS417), RS485
  • Easy and flexible installation
  • Soundless measuring principle
  • Insensitive to dirt, smoke, and humidity
  •  

Technical Data

Mechanical Data

Measuring principle

absolute

Repeat accuracy

+/- 1 mm

System accuracy in µm at 20 °C

+/- (1000 µm + 20 µm x L)
L = measuring length in meters

Distance between sensor
and magnetic tape

4 mm

Basic pole pitch

8 mm

Sensor housing material

Aluminium

Sensor housing dimensions

L x W x H = 355 x 85 x 48 mm

Necessary magnetic tape

AB20-80-10-1-R-D-15-BK80

Max. measuring length

260 m

Cable connection

open cable ends

Weight

ca. 900 g without cable
Cable: ca. 60 g per meter

Ambient temperature

Storage temperature

-25 ... +85 °C

Operation temperature

-10 ... +70 °C
-25 ... +85 °C on request

Protection class

IP54

Electrical Data

Power supply

10 - 30 VDC 

Periodic and random deviation

10 - 30 V: < 10%

Current consumption

max. 0,6 A

Interfaces

CANopen safety (DS406, DS417), RS485

Resolution

1 mm (others on request)

Speed

max. 6 m/s

Sensor cable

3 m standard cable length,
others on request,
drag chain compliant