Measure - Control - Position

LIMAX44 Highrise
  • Heights of up to 1,000 meters
  • Unguided, wear-free technology
  • Contactless and noiseless measuring principle
  • Speed: 16 m/s
  • Distance between sensor and magnetic tape of up to 9 mm
  • Robust measuring principle, insensitive to dirt, smoke, and humidity
  • Easy and flexible mounting
  • High precision and repeatability
  • Absolute position is always and directly available – no referencing even after long power cuts
  • Compatible with many common controllers with absolute encoder interface

Technical Data

Mechanical Data

Measuring principle

absolute

Repeat accuracy

+/- 1 mm

System accuracy in µm at 20 °C

+/- (1000 µm + 20 µm x L)
L = measuring length in meters

Distance between the sensor
and the magnetic tape

9 mm

Basic pole pitch

12 mm

Sensor housing material

Aluminium

Sensor housing dimensions

L x W x H = 420 x 120 x 60 mm

Necessary magnetic tape

AB20-120-10-1-R-D-16

Max. Measuring length

1000 m

Cable connection

open cable ends

Weight

ca. 1100 g without cable
Cable: ca. 60 g per meter

Ambient temperature

Storage temperature

-25 ... +85 °C

Operation temperature

-10 ... +70 °C
-25 ... +85 °C on request

Protection class

IP50

Electrical Data

Power supply

10 - 30 VDC 

Periodic and random deviation

10 - 30 V: < 10%

Current consumption

max. 0,6 A

Interfaces

SSI, CANopen (DS406, DS417), RS422

Resolution

1 mm (others on request)

Speed

max. 16 m/s

Sensor cable

3 m standard cable length,
others on request,
drag chain compliant