Measure - Control - Position

PMIX
  • Wearfree alternative to conventional linear-measuring systems 
  • Based on the series LMIX/EMIX
  • Also in combination with the battery-powered position indicators IZ15E and IZ16E possible
  • Sensor head and magnetic tape integrated
  • Optimal guidance
  • For measuring lengths 200, 400 and 600 mm (others on request)
  • Easy installation

Technical Specifications

Housing

Cylinder - Aluminium; Sensor - die cast zinc

Protection class

Cylinder IP40

Operating temperature

-10 ...+70 °C (-25 ...+85 °C on inquiry)

Storage temperature

-25 ...+85 °C

Output current

max. 20 mA per channel

Outputs

Push/ pull, short circuit proof

Index pulse

Period time depending on operation speed

Resolution / repeating accuracy

LMIX2 = 0.025 mm (at 4 edge triggering) / 0.1 mm
EMIX2 = 0.01 mm (at 4 edge triggering) / 0.01 mm
Z15/Z16 = 0.1 mm/0.1 mm

Operation speed

Z15/Z16 = 2.4 m/s; LMIX2 and EMIX2 depending on input-/output-level, see below

00 - Supply / Output level 10 –30 V / 10 –30 V

Tolerance of supply voltage

+/- 10 %

Consumption

max. 150 mA

Output frequency

100 kHz (per channel A or B)

Operation speed

LMIX max. 4 m/s if optimal evaluation circuit; EMIX max. 4 m/s if optimal evaluation circuit

max. length of cable

30 m

01 - Supply / Output level 10-30 V / TTL Line Driver

Tolerance of supply voltage

+/- 10 %

Consumption

max. 150 mA

output frequency

100 kHz (per channel A or B)

Operation speed

LMIX max. 4 m/s, EMIX max. 4 m/s

max. length of cable

50 m

11 - Supply / Output level 5 V / TTL Line Driver

Tolerance of supply voltage

+/- 5 %, ripple <50 mV

Consumption

max. 200 mA

Output frequency

100 kHz (per channel A or B)

Operation speed

LMIX max. 4 m/s, EMIX max. 4 m/s

max. length of cable

10 m