Measure - Control - Position

Supply voltage | 10-30 VDC stabilized, allowed ripple 5 % max., 5 VDC +/- 2.5 %, allowed ripple < 50 mV |
Consumption | 150 mA max. (10-30 V version), 200 mA max.(5 VDC version) |
Outputs | push/ pull, durable short circuit proofed, with inverted signals, channels A /A‘, B /B‘, Z /Z‘ |
Level of signals | 10-30 V or 5 V-TTL |
Repeating accuracy | +/- 0.01 mm |
Accuracy of the system in µm at 20 °C | +/- (20 + 20 x L) (L= measuring lenght in meters) |
Resolution | 0.01 mm (4 edge-triggered) |
Operation speed | 4 m/s max. - 5V/TTL, 4 m/s max.- 10-30V/HTL (at optimal evaluation) |
Output frequency | 100 kHz per channel A/B /A‘/B‘ |
Distance sensor / tape | 0.8 mm |
Operating temperature | -10 ... +70 °C (-25 ... +85 °C on inquiry) |
Storage temperature | -25 ... +85 °C |
Humidity | 80 % max., non-condensing |
Cable length | with 0.75 mm² cable diameter:
|
Sensor head | zinc die cast, black |
Housing (L x W x H) | Sensor 30 x 10 x 15 mm |
Protection class | IP 67 |
Sensor wire | 30 m max. |
Resolution | 0.01 mm (at 4 edge-triggered) |
Repeating accuracy | +/- 0.01 mm |
Accuracy of the system in µm at 20 °C | +/-(20 + 20 x L) (L=measuring lenght in meters) |
Distance tape / sensor | 0.8 mm max. |
Housing | zinc cast |
Protection class | IP 67 |
Operating temperature | -10 ... +70 °C (-25 ... +85 °C on inquiry) |
Storage temperature | -25 ... +85 °C |
Output current | 20 mA max. per channel |
Index pulse (every 2 mm) | periodic period dependent from operation speed |
Necessary magnetic tape | MB20-20-10-1-R (pole division 2 mm) |
| |
Tolerance / supply voltage | +/- 2.5 %, ripple < 50 mV |
Consumption | 200 mA max. |
Output frequency | 100 kHz (per channel) |
Operation speed | 4.0 m/s max. |
Max. cable length | 10 m |
| |
Tolerance / supply | stabilized, ripple 5 % max. |
Consumption | 150 mA max. |
Output frequency | 100 kHz max. (per channel) |
Operation speed | 4.0 m/s max. |
Max. cable length | 50 m |
| |
Tolerance / supply | stabilized, ripple 5 % max. |
Consumption | 150 mA max. |
Operation speed | 4.0 m/s max. (at optimal evaluation) |
Max. cable length | 30 m |
Input supply voltage | 10-30 VDC stabilized, ripple 5 % max., 5 VDC +/- 2.5 %, ripple < 50 mV |
Consumption | max. 150 mA (10-30 V version), 200 mA max. (5 VDC version) |
Outputs | push/ pull, durable short circuit prooved, with inverted signals, channels A /A‘, B /B‘, Z /Z‘ |
Signal level | 10-30 V or 5 V-TTL |
Index pulse | every 2 mm |
Repeating accuracy | +/- 0.01 mm |
Accuracy of the system in μm at 20 °C | +/- (20 + 20 x L) (L=measuring lenght in meters) |
Resolution | 0.01 mm (4 edge-triggered) |
Operation speed | 4 m/s max. - 5V/TTL, 4 m/s max.- 10-30V/HTL (at optimal evaluation) |
Output frequency | 100 kHz per channel A/B /A‘/B‘ |
Distance sensor / tape | 0.8 mm |
Operating temperature | -10 ... +70 °C (-25 ... + 85 °C on inquiry) |
Storage temperature | -25 ... +85 °C |
Humidity | 80 % max., non-condensing |
Cable lengths | with 0,75 mm² cable diameter:
|
Housing (L x W x H) | 50 x 24 x 26 mm |
Protection class | IP 54 (option V = IP67) |