Measure - Control - Position
Inkremental magnetic length measuring system for angle- and linear movements

Supply voltage | 10-30 VDC stabilized, allowed ripple 5 % max., 5 VDC +/- 2.5%, allowed ripple < 50 mV |
Consumption | 150 mA max. (10-30 V version),200 mA max. (5 VDC version) |
Outputs | push/ pull, durable short circuit prooved, with inverted signals, channels A /A‘, B /B‘, Z /Z‘ |
Level of the signals | 10-30 V or 5 V-TTL |
Repeating accuracy | +/- 0.025 mm |
Accuracy of the system in μm at 20 °C | +/- (25 + 20 x L) |
Resolution | 0.1 mm (single edge triggered); 0.025 mm (4 edge-triggered) |
Operation speed | 4 m/s max. - 5V/TTL, 4 m/s max. - 10-30V/HTL (at optimal evaluation) |
Output frequency | 40 kHz per channel A/B /A‘/B‘ |
Measuring length | 32.0 m max. |
Distance sensor/tape | 2.0 mm max. |
Operating temperature | -10 ... +70 °C (-25 ... +85 °C on inquiry) |
Storage temperature | -25 ... +85 °C |
Humidity | 80 % max., non condensing |
Cable | |
Cable lengths | with 0.75 mm² cable diameter:
|
Sensor head | zinc die cast, black |
Housing | Sensor 30 x 10 x 15 mm |
Protection class | IP 67 |
Sensor wire | 30 m max. |
Resolution | 0.1 mm (at single edge triggering) / 0.025 mm (at 4 edge triggering) |
Repeat accuracy | 0.025 mm |
Accuracy of the system in µm at 20 °C | +/-(25+20xL) (L= measuring length in meters) |
Distance tape / sensor | 2.0 mm max. |
Housing | zinc die cast |
Protection class (sensor head) | IP 67 |
Operating temperature | -10 ...+70 °C (-25 ...+85 °C on inquiry) |
Storage temperature | -25 ...+85 °C |
Output current | 20 mA max. per channel |
Index pulse (every 5 mm) | periodic period dependent from operation speed |
Supply/ output levels 5 VDC / 5 V-TTL line driver output | |
Tolerance / supply | +/- 2.5 %, ripple < 50 mV |
Consumption | 200 mA max. |
Output frequency | 40 kHz max. (per channel) |
Operation speed | 4.0 m/s max. |
Max. cable length | 10 m |
Supply / output levels 10 - 30 VDC / 5 V-TTL line driver output | |
Tolerance / supply | stabilized ripple 5 % max. |
Consumption | 150 mA max. |
Output frequency | 40 kHz max. (per channel) |
Operation speed | 4.0 m/s max. |
Max. cable length | 50 m |
Supply / output levels 10 - 30 VDC / 10 - 30 VDC output | |
Tolerance / supply | stabilized ripple, 5 % max. |
Consumption | 150 mA max. |
Output frequency | 40 kHz max. (per channel) at optimal evaluation |
Operation speed | 4.0 m/s max. (at optimal evaluation) |
Max. cable length | 30 m |