Measure - Control - Position

SMIX with integrated limit switches
  • Integrated limit switches
  • Reference pulses (determinable when ordering)
  • Project-specific manufactured magnetic tape
  • Resolution 0.01 mm
  • Repeat accuracy +/- 0.01 mm
  • Up to 2 mm distance between sensor and magnetic tape possible
  • High protection class IP67

 

 

 

Technical Specifications

Mechanical Data

Measuring principle

incremental

Repeat accuracy

+/- 0.01 mm

System accuracy in µm at 20 °C

+/- (25 + 20 x L)
L = measuring lenght in meter

Distance sensor / tape

max. 2 mm

Pole lenght

5 mm

Housing dimensions (L x W x H)

50 x 12 x 25 mmm

Required magnetic tape

MB20-50-10-2-R-SNXXX

Max. measuring lenght

theoretically unlimited

Contact termination

outgoing cable unit

Weight

517 g (with 8 m cable)

Ambient Conditions

Operation temperature

-10 ... +70 °C,
-25 ... +85 °C on request

Storage temperature

-25 ... +85 °C

Protection class

IP67

Electrical Data

Power supply

10... 30 VDC

Ripple

10... 30 V < 10 %

Current consumption

10 ... 30 VDC: max. 150 mA

Output signals

A, A', B, B', Z, Z
push-pull-outputs (for min/max limit switches)

Output level

5 V TTL Line Driver / 10 ... 30 V HTL

Resolution (4-edge triggering)

max. 0.01 mm

Index pulse

5 mm periodically

Max. output frequency per chanel

80 kHz

Max. drive speed

4 m/s

Sensor cable

lenght: max. 30 m,
cores: 10 x 0.14 mm²
bend radius: min. 60 mm