SMIX Incremental Measuring System Insensitive Linear Encoder with integrated end position detection

  • Integrated limit switches
  • Free defineable reference point
  • Project-specific manufactured magnetic tape
  • Resolution 0.01 mm
  • Repeat accuracy +/- 0.01 mm
  • Up to 2 mm distance between sensor and magnetic tape possible
  • High protection class IP67
Product inquiry

Mechanical data

Measuring principleincremental
Repeat accuracy± 1 increment
System accuracy in µm at 20 °C± 825 + 20 x L), L= measuring length in meters
Distance sensor / tapemax. 2 mm
Sensor housing materialABS plastic
Housing dimensions (L x W x H)50 x 12 x 25 mm
Required magnetic tapeMB20-50-10-1-R
Pole pitch5 mm
 Max. measuring length theoretically unlimited
Connectionsopen cable ends
Sensor cable1.5 m standard length, others on request, drag chain suitable 
Sensor cable bending radius60 mm
Weightapprox. 40 g without cable, cable: approx. 60 g/m

ELEcTRICal DatA

Power supply voltage10 ... 30 VDC or 5 VDC
Residual ripple10 ... 30 VDC: <10 %
Current consumption10 ... 30 VDC: max. 150 mA, 5 VDC: max. 200 mA
Output signalsA, A', B, B', Z, Z'
Output levelsHTL or TTL
Output current per channelmax. 40 mA
Resolution (at 4 edge evaluation)0.01 mm
Index pulse every 5 mm (periodically)
Max. output frequency per channel80 KHz
Max. operating speed4 m/s

Environmental conditions

Storage temperature-25 ... +85 °C
Operating temperature-10 ... +70 °C, -25 ... +85 °C on request
Humidity95 %, non-condensing
Protection classIP67