This website uses cookies

This website uses cookies to improve user experience. By using our website you consent to all cookies in accordance with our Cookie Policy.

LIMIX Length measuring system for lift applications

  • Robust measuring principle for usage in rough environments
  • Insensitive to dirt, smoke and humidity
  • Direct measurement on the elevator car
  • Easy and flexible installation
  • Resolution 0.625 mm (4 edge evaluation)
  • Operating speed up to 5 m/s
  • Polymer guide made of self lubricating material
Product inquiry

 MECHANICAL DATA

Measuring principleincremental
Repeat accuracy± 1 increment
System accuracy in  µm at 20 °C± (25 + 20 x L), L= measuring length in meters
Distance sensor/ tapemax. 2.0 mm
Sensor housing materialsensor head: zinc die cast, guiding block: slidable PA6G oil
Housing dimensions
(L x W x H)
sensor head: 30 x 12.5 x 25 mm, guiding block: 51 x 22 x 32 mm
Required magnetic tapeMB20-50-10-1-R-D-EP-LIFT
Pole pitch5 mm
Max. measuring length600 m
Connectionsopen cable ends, connectors optionally
Sensor cable1.5 m standard length, others on request, drag chain suitable
Sensor cable bending radius 60 mm
Weightsensor head + guiding block: approx. 60 g (without cable); cable: approx. 60 g/m

 ELECTRICAL DATA

Power supply voltage10 ... 30 VDC or 5 VDC
Residual ripple10 ... 30 VDC: <10 %, VDC: ± 25 mV
Current consumption10 ... 30 VDC: max. 150 mA, VDC: max. 200 mA
Output signalsA, A', B, B', Z, Z' resp. R, R'
Output levelsHTL or TTL
Output current per channelmax. 20 mA
Resolution (at 4 edge evaluation)0.625 mm
Index pulseevery 5 mm (periodically)
Max. output frequency per channel4 kHz
Operating speed5 m/s (at HTL and optimal evalution)

ENVIRONMENTAL CONDITIONS

Storage temperature-25 ... +85 °C 
Operating temperature-10 ... +70 °C, -25 ... +85 °C on request
Humiditiy95 %, non-condensing
Protection classIP67

FLYER

Flyer LIMIX

OPERATION MANUAL

LIMIX