MTM-I encoder magnetico incrementale traslazionale rilevamento di posizione resistente all'usura in barre rotonde

  • sistema di misurazione con un singolo binario codificato e sensore
  • rilevazione di lunghezza e posizione di cilindri idraulici
  • progettazione incrementale con due risoluzioni
  • misurazione magnetica resistente all' usura e senza contatto
  • molto robusto, resistente allo sporco
  • resistente agli choc e resistente alle vibrazioni
  • possibile alimentazione di 10 ... 30 VDC o 5 VDC
  • livello di uscita in formato HTL o TTL

> Sensor Solutions for Mobile Automation

Richiedi prodotto

MECHANICAL DATA

Measuring principleincremental
Repeat accuracy± 1 increment
System accuracy in µm at 20 °C± (160 + 20 x L), L = measuring length in meters
Distance sensor / piston rodmax. 1.0 mm
Sensor housing materialsensor system is integrated in the round resp. piston rod
Housing dimenionsdepending on used piston rod and stroke length
Required magnetic tapecoded round resp. piston rod
 Pole pitch of piston rod5 mm,
Maximum measuring length5000 mm
Connectionsstandard: open cable ends, optional: 9 pin D-SUB or 8 pin M12 round connector
Sensor cable1,5 m standard length, others on request,
drag chain suitable
Sensor cable bending radius60 mm
Weightdepends on measuring length  (= stroke length to be monitored) and application ; cable: approx. 60 g/m

ELECTRICAL DATA

Power supply voltage 10 ... 30 VDC or 5 VDC
Residual ripple10 ... 30 VDC: < 10%, 5 VDC: ± 25 mV
Current consumption10 ... 30 VDC: max. 150 mA, 5 VDC: max. 200 mA
Output signals A, A', B, B', Z, Z'
Output levelsHTL or TTL
Output current per channelmax. 20 mA
Resolution (at 4 edge evaluation)0.025 mm
Index pulseevery 5 mm (periodically)
Max. output frequency per channel100 kHz
Operating speed4 m/s

eNVIRONMENTAL cONDITIONS

Storage temperature-25 ... +85 °C
Operating temperature-10 ... +70 °C, -25 ... +85 °C on request
Humiditiy95 %, non-condensing
Protection classsensor system: standard: IP67, optional: IP69K
mechanical system: depending on used piston rod and material

MECHANICAL DATA

Measuring principleincremental
Repeat accuracy± 1 increment
System accuracy in µm at 20 °C± (1000 + 20 x L), L = measuring length in meters
Distance sensor / tapemax. 7.0 mm
Sensor housing materialsensor system is integrated in the round resp. piston rod
Housing dimentionsdepending on used piston rod and stroke length
Required magnetic tapecoded round resp. piston rod
 Pole pitch of piston rod16 mm
Maximum measuring length5000 mm
Connectionsstandard: open cable ends, optional: 9 pin D-SUB or 8 pin M12 round connectorr
Sensor cable1,5 m standard length, others on request,
drag chain suitable
Sensor cable bending radius60 mm
Weightdepends on measuring length (= stroke length to be monitored) and application ; cable: approx. 60 g/m

ELECTRICAL DATA

Power supply voltage 10 ... 30 VDC or 5 VDC
Residual ripple10 ... 30 VDC: < 10 %, 5 VDC: ± 25 mV
Current consumption10 ... 30 VDC: max. 150 mA, 5 VDC: max. 200 mA
Output signals A, A', B, B', Z, Z'
Output levelsHTL or TTL
Output current per channelmax. 20 mA
Resolution (at 4 edge evaluation)1.0 mm
Index pulseevery 16 mm (periodically)
Max. output frequency per channel5 kHz
Operating speed4 m/s

eNVIRONMENTAL cONDITIONS

Storage temperature-25 ... +85 °C
Operating temperature-10 ... +70 °C, -25 ... +85 °C on request
Humiditiy95 %, non-condensing
Protection classsensor system: standard: IP67, optional: IP69K
mechanical system: depending on used piston rod and material

 

 

FLYER

Flyer MTM-I