PMIX Unité linéaire guidée Subsitution du potentiomètre numérique par des capteurs magnétiques ELGO
- Alternative sans usure aux systèmes de mesure linéaire conventionnels
- Basé techniquement sur la série LMIX / EMIX
- Également possible en combinaison avec les indicateurs de position à piles IZ15E et IZ16E
- Tête de capteur et bande magnétique intégrées
- Guidance optimale
- Pour des longueurs de 200, 400 et 600 mm (autres sur demande)
- Montage facile
Mechanical DATA
Measuring principle | incremental |
Repeat accuracy | ± 1 increment |
System accuracy in µm at 20 °C | LMIX: ± (25 + 20 x L), EMIX: ± (20 + 20 x L), L= measuring length in meters |
Distance sensor / tape | fixed by guide carriage |
Sensor housing material | cylinder: Aluminium, sensor: plastic |
Housing dimensions | L: 60 mm + measuring range, W x H: 43 x 46 mm |
Required magnetic tape | EMIX: MB20-20-10-1-R, LMIX: MB20-50-10-1-R |
Pole pitch | EMIX: 2 mm, LMIX: 5 mm |
Max. measuring length | 600 mm |
Connections | open cable ends |
Sensor cable | 1.5 m standard length, others on request, drag chain suitable |
Sensor cable bending radius | 60 mm |
Weight | approx. 50 g at 200 mm measuring, length without cable, cable: approx. 60g/m |
ELEcTRICal DatA
Power supply voltage | 10 ... 30 VDC or 5 VDC |
Residual ripple | 10 ... 30 VDC: < 10 %, 5 VDC: ± 100 mV |
Current consumption | 10 ... 30 VDC: max. 150 mA, 5 VDC: max. 200 mA |
Output signals | A, A', B, B', Z, Z', |
Output levels | HTL or TTL |
Output current per channel | max. 20 mA |
Resolution (at 4 edge evaluation) | LMIX: 0.025 mm, EMIX: 0.01 mm, EMIX23: 0.001 mm, IZ series: 0.01 mm |
Index pulse | EMIX: every 2 mm (periodically), EMIX: every 5 mm (periodically) |
Max. output frequency per channel | LMIX: 80 KHz, EMIX: 200 KHz, EMIX23: 1 MHz |
Max. operating speed | LMIX: 4m/s, EMIX/ IZ series: 4 m/s, EMIX23: 2 m/s |
Environmental conditions
Storage temperature | -25 ... +85 °C |
Operating temperature | -10 ... +70 °C, -25 ... +85 °C on request |
Humidity | 95 %, non-condensing |
Protection class | cylinder: IP40, sensor: IP65 |