IZ15E Misurazione e sistema di visualizzazione Indicatore di posizione con sensore magnetico alimentato a batteria

  • display  LCD a 7 posizioni dotato di sensore magnetico fisso
  •  facile da montare con custodia snap-in 
  • risoluzione fino a 0,01 mm
  • simbolo "°" per visualizzare l'angolo
  • rappresentazione in decimali o frazione di pollici
  • scomparto della batteria interno o esterno
  • programmabile ampliamente e individualmente
  • opzione: interfaccia RS-232 (IZ16E-100)

Richiedi prodotto

MECHANICAL DATA

Housingnorm panel housing
Housing materialplastic, black
Housing dimensions (W x H)72 x 48 mm
Panel cut out (W x H)68 x 45 mm
Keyboardfoil with short stroke keys
Installation depth (complete)min.30 mm, depends on version

ELECTRICAL DATA

Display7 digit LCD (digit height 9 mm), with sign, battery status and measurement units
Perspective12 o'clock
Measurement unitsmm / inch / m 
Accuracy± 1 digit
Power supply voltagebattery  (1.5 V resp. 3 V), integrated or external
Current consumption< 1 mA bei 1.5 V (with measuring system)
Battery service life1 ... 3 years (depending on battery type)
Optional interfacesRS232, version IZ15E-100
Connectionsfixed cable outlet
Data memoryFlash

ENVIRONMENTAL CONDITIONS

Operating temperature0 ... +50 °C
Storage temperature-10 ... +60 °C
Humiditymax. 80 %, non-condensing
Protection class (front)IP54 
Protection class (rear)IP40

MAGNETIC SENSOR

Type designationMS-250
Dimensions (L x B x H)30 x 10 x 15 mm
Measuring principlemagnetic, incremental
Required magnetic tapeMB-20-25-10-1-R
Magnetic tape pole pitch2.5 mm
Distance sensor/ tapemax. 0.8 mm
Resolution0.1 ... 0.01 mm
Repeat accuracy±2 increments
Operation speedmax. 4 m/s
Housing materialzinc die cast
Protection classIP67
Connectionsfixed connection with indicator
Sensor cabledrag-chain suitable, 6-wire, twisted pairs and double-shielded
Sensor cable length0.1 ... 2.0 m
Sensor cable bending radiusmin. 60 mm
Weightapprox. 30 g
Humiditymax. 95 %, non-condensing
Influence of external magnetic fieldsexternal magnetic fields > 1 mT, which directly impinge upon the sensor, can affect the system accuracy.