strumento lineare guidato Sistema di misurazione di lunghezza magnetico incrementale per le presse piegatrici

  • per l'impiego nelle presse piegatrici
  • alternativa alle righe ottiche interessante per il prezzo
  • montaggio semplice su preesistenti presse piegatrici
  • risoluzione massima  di 0,001 mm (con decodifica del segnale su 4 fronti e valutazione del cambio di stato)
  • unità di guida di alta qualità
  • resistente allo sporco, a scosse e vibrazioni
  • nuovo: impulso di zero liberamente configurabile
Richiedi prodotto

Mechanical DATA

Measuring principle incremental
 Measuring length max. 1000 mm
Distance sensor / tape fixed by guide carriage
Housing dimensions
(L x W x H)
guide unit: 80 x 54 x 31 mm (without cable),
guide rail: (150 + measuring length) x 55 x 20 mm
Housing material sensor head: zinc die cast,
guiding carriage: aluminium
Connection type open cable ends, connectors optionally
Sensor cable 1.5 m standard length, others on request, drag chain suitable 
Weight approx. 620 g at 330 mm measuring length

ELEcTRICal DatA

Power supply voltage 10 ... 30 VDC or 5 VDC
Residual ripple 10 ... 30 VDC: <10%,
5 VDC: ± 25 mV
Consumption 10 ... 30 VDC: max. 50 mA,
5 VDC: max. 100 mA (with unloaded outputs)
Repeat accuracy ± 1 increment (without consideration of mechanical influences)
System accuracy ± (25 + 20 x L)
L= measuring length in meter (without consideration of mechanical influences)
Output signals channels A, A', B, phases shifted by 90° (phase shift ± 20%)
Output level HTL or TTL (depends on order information)
Reference pulse position adjustable
Output current  max. 20 mA per channel
Resolution (at 4 edge evaluation) depends on order information
Max. output frequency per channel depends on selected resolution
Max. operating speed

depends on selected resolution,
e.g. mx.  m/ss at 0.1 mm resolution

Environmental conditions

Storage temperature -25 ... +85 °C
Operating temperature -10 ... +70 °C, -25 ... +85 °C on request
Humidity 95%, non-condensing
Protection class sensor head: IP67, mechanical parts: IP54

FLYER