EMIX23 Incremental measuring System Precise Linear Encoder with 0,001 mm resolution
- High resolution sensor technology (1µm)
- Resolution 0.001 mm (at 4 edge triggering)
- Repeat accuracy ± 0.001 mm
- Speed-proportional square wave outputs
- With index pulse (periodically) or free definable reference pulse
- Distance monitoring LED available (option)
- Predestined for control technology applications
Mechanical DATA
Measuring principle | incremental |
Repeat accuracy | ± 1 increment at resolutions > 10 µm ± 2 µm at resolutions ≤ 10 µm |
System accuracy in µm at 20 °C | ± (20 + 20 x L); L= measuring length in meters |
Distance sensor / tape | max. 0.8 mm |
Sensor housing material | zinc die cast |
Housing dimensions (L x W x H) | 30 x 12.5 x 25 mm |
Required magnetic tape | MB20-20-10-1-R-EPS |
Pole pitch | 2 mm |
Max. measuring length | theoretically unlimited |
Connections | open cable ends, optionally with connector |
Sensor cable | 1.5 m standard length, others on request, drag chain suitable |
Sensor cable bending radius | 60 mm |
Weight | approx. 35 g without cable, cable: approx. 60g/m |
ELEcTRICal DatA
Power supply voltage | 10 ... 30 VDC or 5 VDC |
Residual ripple | 10 ... 30 VDC: <10 %, 5 VDC: ± 25 mV |
Current consumption | 10 ... 30 VDC: max. 150 mA, 5 VDC: max. 200 mA |
Output signals | A, A', B, B', Z, Z' resp. R, R' |
Output levels | HTL or TTL |
Output current per channel | max. 20 mA |
Resolution (at 4 edge evaluation) | up to 0.001 mm |
Index pulse | every 2 mm (periodically) optionally as reference pulse |
Max. output frequency per channel | 1 MHz, higher on request |
Max. operating speed | 2 m/s |
Environmental conditions
Storage temperature | -25 ... +85 °C |
Operating temperature | -10 ... +70 °C, -25 ... +85 °C on request |
Humidity | 95 %, non-condensing |
Protection class | IP64, higher on request |