EMSC Incremental Measuring Systems Magnetic Length Measurement with 1 Vpp sine-cosine output
- Speed proportional sin/cos signal outputs
- 2 mm movement results in one sin/cos period
- Reading distance up to 0.8 mm
- EMSC1: external evaluation unit
- EMSC2: integrated evaluation unit, small design
Mechanical data
Measuring principle | incremental |
Repeat accuracy | depends on interpolation unit |
System accuracy in µm at 20 °C | ± (20 + 20 x L), L= measuring length in meters |
Distance sensor / tape | max. 0.8 mm |
Sensor housing material | zinc die cast |
Housing dimensions (L x W x H) | EMSC1 sensor: 30 x 10 x 15 mm, translator box: 72 x 24 x 48 mm EMSC2 sensor: 30 x 12,5 x 25 mm |
Required magnetic tape | MB20-20-10-1-R |
Pole pitch | 2 mm |
Max. measuring length | theoretically unlimited |
Connections | EMSC1: M16 round connector, EMSC2: open cable ends |
Sensor cable | 1.5 m, others on request, drag chain suitable |
Sensor cable bending radius | 60 mm |
Weight | EMSC1 sensor head: approx. 40 g, EMSC1 translator box: approx. 150 g, EMSC2 sensor head: approx. 35 g, each without cable, cable: approx. 60 g per meter |
ELEcTRICal DatA
Power supply voltage | EMSC1: 10 ... 30 VDC or 5 VDC EMSC2: only 5 VDC, 10 ... 30 VDC on request |
Residual ripple | 10 ... 30 VDC: <5 % 5 VDC: ± 25 mV |
Current consumption | 10 … 30 VDC: max. 50 mA 5 VDC: max. 120 mA |
Output signals | Sin+, Cos+, Sin-, Cos- |
Output levels | 1 Vss |
Output current per channel | max. 20 mA |
Resolution | 2 mm signal period |
Index pulse | not available |
Max. output frequency per channel | 10 kHz |
Max. operating speed | 10 m/s |
Environmental conditions
Storage temperature | -25 ... +85 °C |
Operating temperature | -10 ... +70 °C, -25... +85 °C on request |
Humidity | 95 %, non-condensing |
Protection class | EMSC1: IP67, translator box: IP40 EMSC2: IP64, higher on request |