IZBox-600 Measurement and Transmission System With wireless 868 MHz radio transmission of the actual value
- Integrated 868 MHz wireless module
- High performance ceramic antenna (integrated)
- Transmission range up to 200 meters (with intervisibility)
- Four resolutions selectable (0.01 / 0.05 / 0.10 / 1.00 mm)
- Measuring system for linear or rotative measurements
- Integrated battery case (with cover) for 1.5 V mono cell
- Two status LEDs for first start up (can be switched off)
- RF transmission cyclically or released by external input
- Reset of the measurement value by external input
- System configuration settings via DIP switches
- Easy to install (via mounting holes or optionally by snap-on attachment for top hat rails)
- Auto Power Off function at sensor inactivity
- Auto Power On at sensor movement
Mechanical data
| Housing (Evaluation units) | ABS plastic, black |
| Housing dimensions (L X W x H) | 150 x 80 x 39.5 mm |
| Total height | 67 mm (incl. senor connector) |
| Mounting | standard: four mounting holes and two 30 mm slotted holes for M4 screws optional: snap-on attachment for top hat rail |
electrical data
| System configuration | via 32 DIP switches |
| System resolution (adjustable) | 0.01 / 0.05 / 0.10 / 1.00 mm |
| Power supply voltage | 1.5 V battery (type D, mono cell) |
| Current consumption | < 1 mA at 1.5 V during normal operation without radio transmission approx. 5 mA at 1.5 V during continuous radio transmission |
| Battery Service life | 1 … 3 years (depending on battery type and effective on-time) |
| External inputs | 2 (via RJ45 socket) - manual reset (measurement value) - manual wireless transmission |
| Accessory | RF-MODULE 868 MHz RS232 (Box), RF-MODULE 868 MHz USB (Stick), IZ16-620: external slave indicator Snap-on attachment for top hat rail (Art. No. 764000006) |
Environmental conditions
| Operating temperature | 0 ... +50 °C |
| Storage temperature | -10 ... +60 °C |
| Humidity | max. 80 %, non-condensing |
| Protection class | IP40 |
868 MHz SpezifikaTIons
| Range | up to 200 m (by intervisibility) |
| HF-data rate | 38 kbps |
| Power output | typ 2 dBm e.i.r.p. (10 dBm an 50?) |
| Input sensitivity | up to -102 dBm (-110 dBm an 50?) |
| FrFrequency range | 863 - 868.6 MHz |
| Channel spacing | 50 kHz |
| Modulation method | 2-FSK, MSK |
| Antenna | integrated ceramic antenna |
| Topology | point to point |
| Transmission | bi-directional, half-duplex, with receipt, with CRC-checksum calculation, five-time repeating of non-acknowledged radio telegrams |
| Addressing | 2 byte address space, max. 64000 different addresses |
| Conformity (Europe) | EN 300220-1, EN 301489-1/-3, EN 60950-1, EN 50371 |
magnetic sensor
| Type designation | MS-250 |
| Dimensions (L x W x H) | 30 x 10 x 15 mm |
| Measurement principle | magnetic, incremental |
| Required magnetic tape | MB20-25-10-1-R (for linear measurements) |
| Required magnetic ring | MR 3848 (for rotative applications) |
| Pole pitch (magnetic tape/ ring) | 2.5 mm |
| Distance sensor- magnetic tape | max. 0.8 mm |
| Resolution | 0.1 ... 0.01 mm |
| Repeat accuracy | ± 2 inkrements |
| Maximum measuring length | theoretically unlimited |
| Operation speed | max. 4 m/s |
| Housing material | zinc die cast |
| Protection class | IP67 |
| Connections | round connector |
| Sensor cable | drag-chain suitable, 6-wire, twisted pairs and double-shielded |
| Sensor cable length | 0.1 bis max. 2.0 m |
| Sensor cable bending radius | min. 60 mm |
| Weight | ca. 30 g |
| Operating temperature | 0 ... +50 °C |
| Storage temperature | -10 ... +60 °C |
| Humidity | max. 95 %, non-condensing |
| Influence of external magnetic fields | external magnetic fields > 1 mT, which directly impinge upon the sensor, can affect the system accuracy |