Magnetic Tape MB20 | AB20 incremental or absolute coded
magnetic tape layout
A the cover tape is used for the mechanical protection of the magnetic tape and is glued onto the magnetic plastictape after installation
B magnetic tape band made of plastic
C magnetic conductable stainless steel tape protects from mechanical damages and is a magnetic short circuit
mechanicAL DatA
Linear extension (relative) | ?L = L x ? x ??, L = measuring length in meters, ?? = relative change of temperature in °K, based on 20 °C room temperature |
Coefficient of extension ? | 16 x 10 –6 1/K |
Bending radius | min. 150 mm |
Available widths | 10 mm ± 0,2 mm, 20 mm ± 0,3 mm, 5 mm ± 0,1 mm (on request), 2 mm ± 0,1 mm (on request) |
Thickness | 1.8 mm ± 0,1 mm (tape layout R), 1.5 mm ± 0,1 mm (tape layout A) |
Max. available length | incremental: standard roll 32 m (up to 70 m on request) absolute: up to 600 m (others on request) |
Electrical DatA
Pole length | see type designation |
Number of tracks | see type designation |
Influence of external magnets | external magnetic fields must not exceed 64 mT (640 Oe; 52kA/m) at the surface of the magnetic tape. Higher values will damage or destroy the magnetic tape code. Magnetic fields > 1 mT at the measuring system has negative influences on the accuracy of the system |
Environmental CONDITIONS
Working temperature range | 0 ... 70 °C |
Operating temperature range | -20 ... 85 °C |
Storage temperature | -40 ... 95 °C |
Operating height | max. 2000 m above N.N. |
Humidity | max. 80 %, not-condensing |
Protection class | IP67 |
Magnetic Tape Cover Profile