Inductive Rotor Position Sensor IRM for integration into electric drives
- Mechanically customizable built-in encoder
- Ideal for detecting pole position, angle, and rotational speed
- Non-contact measurement via inductive sensing
- Stable sin/cos output signals matched to the number of pole pairs of the synchronous machine
- Compatible with all standard controllers and inverters featuring a sin/cos interface
ADVANTAGES
- Integrates into any motor design in minimal space with generous mounting tolerances
- Absolute measurement – immediate signal output upon power-up without homing
- Magnet-free and immune to stray magnetic fields
- High sensor accuracy positively impacts the energy efficiency of the drive
MECHANICAL DATA - BUILT-IN-ENCODER
| Air gap (nominal) | max. 2.0 mm |
MECHANICAL DATA - STATOR
| Material | FR4 |
| Outer diameter | 52 ... 200 mm |
| Mounting methods | gluing, clamping, screw mounting on request |
| Axiale installation height | min. 10.6 mm |
MECHANICAL DATA - ROTOR
| Material | conducting material ≥ 35 µm (PCB, aluminum, steel) |
| Speed | ≤ 100 000 min-1, depending on pole count, mounting method, diameter, and material |
| Shaft diameter | 2 ... 138 mm |
ELECTRICAL DATA
| Supply voltage | 5 V DC |
| Current consumption (no load) | < 30 mA |
| Output signals (single ended) | sin / cos |
| Output level (single ended) | 3 Vpp, depending on output current and temperature |
| Accuracy per period | < 0,5° electrical |
| Latency | > 5 µs |
| Number of periods per mecanical revolution | 1 ... 64 |
| Frequeny range | 0 ... 10 kHz |
| Recommended output current | < 5 mA |
ENVIRONMENTAL CONDITIONS
| Operating temperature | -40 °C ... +125 °C acc. to ISO 16750-4:2010, short-term up to +150 °C (depending on the availability of the safety function, operating temperature range, and service life / MTTF value) |
| Storage temperature | -40 °C ... +125 °C |
* Information without guarantee, subject to change