EMIX1 | EMIX2 Incremental Measuring Systems Compact Measuring Systems for linear and radial measurements
- Resolution 0.01 mm (at 4-edge triggering)
- Repeat accuracy ± 0.001 mm
- Speedproportional output of square-waves signals
EMIX1
- small sensor head with external electronic interpolation
EMIX2
- Small sensor with integrated electronic interpolation
- The installation of the sensor can be effected vertical or horizontal
Mechanical DATA
Measuring principle | incremental |
Repeat accuracy | ± 1 increment |
System accuracy in µm at 20 °C | ± (20 + 20 x L), L= measuring length in meters |
Distance sensor / tape | max. 0.8 mm |
Sensor housing material | zinc die cast |
Housing dimensions (L x W x H) | EMIX1: 30 x 10 x 15, EMIX2: 30 x 12.5 x 25 |
Required magnetic tape | MB20-20-10-1-R |
Pole pitch | 2 mm |
Max. measuring length | theoretically unlimited |
Connections | EMIX1: 9 pin D-SUB (male), EMIX2: open cable ends |
Sensor cable | 1.5 m standard length, others on request, drag chain suitable |
Sensor cable bending radius | 60 mm |
Weight | EMIX1: sensor + D-SUB: approx. 40 g, EMIX2: approx. 35 g (each without cable), cable: approx. 60 g/m |
ELEcTRICal DatA
Power supply voltage | 10 ... 30 VDC or 5 VDC |
Residual ripple | 10 ... 30 VDC: <10 %, 5 VDC: ± 25 mV |
Current consumption | 10 ... 30 VDC: max. 150 mA, 5 VDC: max. 200 mA |
Output signals | A, A', B, B', Z, Z' |
Output levels | HTL or TTL |
Output current per channel | max. 20 mA |
Resolution (at 4 edge evaluation) | 0.01 mm |
Index pulse | every 2 mm (periodically), optionally as reference pulse (EMIX2) |
Max. output frequency per channel | 200 KHz |
Max. operating speed | 4 m/s |
Environmental conditions
Storage temperature | -25 ... +85 °C |
Operating temperature | -10 ... +70 °C, -25 ... +85 °C on request |
Humidity | 95 %, non-condensing |
Protection class | EMIX1: IP67, EMIX2: IP64, higher on request |