HMIX1X measuring system with 0.001 mm resolution with 1 µm resolution ideal for precision motor feedback

  •     1 µm resolution
  •     High measuring accuracy
  •     Periodic index pulse or freely definable reference pulse possible
  •     Direct non-contact measurement
  •     Insensitive to dust, dirt and water
Product inquiry

Mechanical DATA

Measuring principle incremental
Repeat accuracy ±1 µm
System accuracy in µm at 20 °C

±(15 + 20 x L); L= measuring length in meters

Distance sensor / tape max. 0.2 mm or 0.5 mm when used without magnetic band
Sensor housing material zinc die cast
Housing dimensions
(L x W x H)
38 x 11 x 15 mm
Required magnetic tape MB20-10-10-1-R
Pole pitch 1 mm
 Max. measuring length theoretically unlimited
Connections open cable ends, optionally with connector
Sensor cable 1.5 m standard length, others on request, drag chain suitable 
Sensor cable bending radius 60 mm
Weight approx. 35 g without cable, cable: approx. 60g/m

ELEcTRICal DatA

Power supply voltage 5 VDC
Residual ripple ±25 mV
Current consumption max. 200 mA
Output signals A, A', B, B', Z, Z'
Output levels TTL
Output current per channel max. 20 mA
Resolution (at 4 edge evaluation) 0.001 mm
Index pulse every 1 mm periodically
Max. output frequency per channel 1 MHz, higher on request
Max. operating speed 2 m/s

Environmental conditions

Storage temperature -25 ... +85 °C
Operating temperature -10 ... +70 °C, -25 ... +85 °C on request
Humidity 95 %, non-condensing
Protection class IP67

FLYER

Flyer HMIX1X

OPERATION MANUAL