LMIX22 Incremental measuring System for Contactless linear and rotative measurements
- With periodic index pulse or optional reference pulse
- Distance sensor/tape up to 2.0 mm
- Customized programming of different resolutions
- Differential 10... 30 V-HTL or 5 V-TTL Line Driver outputs
- Speed proportional output of square-wave signals
- Small sensor with integrated evaluation electronic
Product inquiry
Mechanical DATA
Measuring principle | incremental |
Repeat accuracy | ± 1 increment at 10 µm resolution |
System accuracy in µm at 20 °C | ± (25 + 20 x L), L= measuring length in meters |
Distance sensor / tape | max. 2.0 mm |
Sensor housing material | zinc die cast |
Housing dimensions (L x W x H) | 30 x 12.5 x 25 mm |
Required magnetic tape | MB20-50-10-1-R |
Pole pitch | 5 mm |
Max. measuring length | theoretically unlimited |
Type of Connection | open cable ends, optional with plug |
Sensor cable | 1.5 m standard length, others on request, drag chain suitable |
Sensor cable bending radius | 60 mm |
Weight | approx. 35 g without cable, cable: approx. 60g/m |
ELEcTRICal DatA
Power supply voltage | 10 ... 30 VDC or 5 VDC |
Residual ripple | 10 ... 30 VDC: <10 %, 5 VDC: ± 100 mV |
Current consumption | 10 ... 30 VDC: max. 150 mA, 5 VDC: max. 200 mA |
Output signals | A, A', B, B', Z, Z', resp. R, R' |
Output levels | HTL or TTL |
Output current per channel | max. 20 mA |
Resolution (at 4 edge evaluation) | depends on order |
Index pulse | every 5 mm (periodically) opionally as reference pulse |
Max. output frequency per channel | TTL: 100 KHz at 4 m/s, HTL: 100 KHz at 4 m/s and optimal evaluation |
Max. operating speed | 4 m/s at 25 µm resolution |
Environmental conditions
Storage temperature | -25 ... +85 °C |
Operating temperature | -10 ... +70 °C, -25 ... +85 °C on request |
Humidity | 95 %, non-condensing |