AZ16E-300 Absolute Measurement with Indicator Position measurement and visualization for up to 3 axes
- 7-digit LCD display
- Adjustable reference value
- Sign, battery status, units and ,,° '' - symbol
- Configurable display modes: mm/inch incl. fraction display
- Adjustable counting direction
- Adjustable decimal point and multiplicator factor
- Key lock
- Easy mounting via snap-in housing (compatible to Z16)
- Up to three external magnetic sensors (switchable)
- Switch-over between incremental and absolute measuring
- 3 adjustable tool-Offsets
- Optional 2 external inputs for special functions via RJ45
- Optional 2 external outputs via RJ45
- Possible interfaces RS232/RS422/RS485/868 MHz
Product inquiry
MECHANICAL DATA
Housing | norm panel housing |
Housing material | ABS plastic, black |
Housing dimensions (W x H) | 96 x 72 mm |
Panel cut out (W x H) | 93 x 67 mm |
Keyboard | foil with short stroke keys |
Installation depth (complete) | 38 mm |
ELECTRICAL DATA
Display | 7 digit LCD with sign, battery state and measurement units |
Perspective | 12 o'clock |
Measurement units | mm / inch / m |
Accuracy | ± 1 digit |
Power supply voltage | battery (1.5 V resp. 3 V), integrated or external |
Current consumption | < 1 mA bei 1.5 V, with measuring system |
Battery Service life | up to 4 years, depending on power-on time |
Interface | RS485 |
External inputs | 2 x 5 ... 30 V (on request) |
External outputs | 2 x 30 V open collector (on request) |
Connections | standard: RJ45 socket, optional: fixed cable outlet |
Data memory | Flash |
ENVIRONMENTAL CONDITIONS
Operating temperature | 0 ... +50 °C |
Storage temperature | -10 ... +60 °C |
Humidity | max. 80 %, non-condensing |
Protection class (front) | IP54 |
Protection class (rear) | IP40 |
MAGNETIC SENSOR
Type designation | AZS-100 (standard), AZS-50 (on request) |
Dimensions (L x W x H) | 100 x 12 x 25 mm |
Measuring principle | magnetic, absolute |
Required magnetic tape | AB20-40-10-1-R-11 |
Magnetic tape pole pitch | 4 mm |
Distance sensor/ tape | 1.5 mm |
Resolution | 0.1 mm |
Repeat accuracy | ±2 increments |
Interface (absolute) | RS485 |
Maximum measuring length | 8.0 m |
Housing material | plastic ABS |
Protection class | IP67 |
Connections | RJ45 (male) connector |
Sensor cable | drag-chain suitable, high-flexible, 4-wire/ shielded |
Sensor cable length | 1, 2, 3, 5 m, others on request, maximum cable length 20m |
Sensor cable bending radius | min. 25 mm |
Weight | approx. 40 g |
Humidity | max. 95 %, non-condensing |
Influence of external magnetic fields | external magnetic fields > 1 mT, which directly impinge upon the sensor, can affect the system accuracy. |