Z60 3 Axes Position Indicator / Counter Programmable Universal Position Indicator for 3 axes
- Position indicator with signal inputs for 1 up to 3 axes
- Inputs for conventional encoders as well as for ELGO measuring systems (incremental or absolute)
- Adjustable reference value, tool-offset and saw blade thickness
- Digital control input (configurable) for each axis
- Modes for pulses, speed and concentricity
- 2 open drain and 2 relay outputs
- Optional analog output available
- Power down memory
- Serial RS232 interface
- quasi-absolute version Z60-014 by integrated rechargeable battery-line
mechanical data
Housing | norm panel housing |
Housing material | aluminium |
Housing dimensions (W x H) | 96 x 72 mm |
Panel cut out (W x H) | 93 x 67 mm |
Keyboard | foil with short stroke keys |
Installation depth | 33 mm (without connectors) |
electrical data
Display | graphic LCD display 120 x 180 pixels |
Perspective | 6 o'clock |
Measurement units | mm, m, Inch, RPM oder ° |
Accuracy | ± 1 digit |
Power supply voltage | 24 VDC ± 20 % |
Current consumption | 120 mA (without measuring system) |
Encor supply | 24 VDC or 5 VDC (order designation) |
Load by encor/ measuring system | max. 300 mA |
Singnal inputs | HTL, TTL, or RS422 (order designation) |
Signal channels | A, B, Z bzw. A, A', B, B', Z, Z' or RxD+, RxD- |
Maximum input frequency | 100 kHz, 500kHz on request |
External inputs | 3 control inputs (24 V, PNP) |
Analog inputs | optional: 0 ... 10 V or 0 ... 20 mA on request |
Relay outputs | 2 potential free shutters (24 VDC / max. 1 A) |
External outputs | 2 open drain outputs |
Analog outputs | optional: 0 ... 10 V or 4 ... 20 mA |
Interfaces | RS232 |
Connections | pluggable screw terminals and 9 pin female D-SUB (for third axis) |
Power down memory | FRAM |
optional accessories | external power pack NG24.0 |
environmental conditions
Operating temperature | 0 ... +50 °C |
Storage temperature | -40 ... +70 °C |
Humidity | max. 80 %, non-condensing |
Protection class (front) | IP43 (installed state) |
Protection class (rear) | IP40 |
Mechanical Data indicator
Housing | panel housing |
Housing material | aluminium |
Housing dimensions (W x H) | 72 x 96 mm |
Panel cut out (W x H) | 67 x 93 mm |
Keyboard | foil with short stroke keys |
Installation depth | 100 mm (with connectors) resp. 37 mm (without connectors) |
electrical Data indicator
Display | graphical LCD (80 x 120 pixel) |
Measurement units | mm or Inch |
Accuracy | ± 1 digit |
Power supply voltage | 14 ... max. 30 VDC |
Reverse polarity voltage | integrated |
Current consumption | max. 600 mA (incl. sensor load) |
External inputs | 3 control inputs 24 V, PNP |
External outputs | 3 control outputs 24 V, PNP |
Interface | RS485 for communication with PLC |
Connections | 1 x 5-pin and 1 x 9-pin Phoenix connector; 3 x 7-pin M9 round connector (sensors) |
Power down memory | FRAM for parameters |
Battery operating time | sensor supply up to 6 or 12 weeks after power-off (depending on selected mode) |
Battery standby current | approx. 160 µA |
Optional accessories | NG24.0 (external power supply) |
mechanical daten (Sensor MS2060)
Housing material | zinc die cast |
Dimensions (L x W x H) | 30 x 10 x 15 mm |
Measuring principle | magnetic, quasi-absolute |
Required magetic tape | MB20-50-10-1-R |
Magnetic tape pole pitch | 5.0 mm |
Distance sensor - tape | max. 2.0 mm |
Max. measuring length | theoretically unlimited |
Operating speed | normal mode: max. 2.0 m/s enery safe mode: max. 0.5 m/s |
Connections | 3 screwable 7-pin M9 round connectors |
Sensor cable | drag-chain suitable, 6-wire, twisted pairs and double-shielded |
Sensor cable lengthe | 2.5 m (standard), others on request |
Cable bending radius | min. 60 mm |
Weight (without cable) | approx. 30 g (cable approx. 60 g/m) |
electrical data (Sensor MS2060)
Resolution | 0.01 mm |
Repeat accuracy | ±0.05 mm |
System accuracy | ±(25 + 20 x L), L=measuring length in ,eter |
environmental conditions entire system
Storage temperature | -20 ... +70 °C |
Operating temperature | 0 ... +50 °C |
Humidity | max. 80 %, non condensing |
Protection class indicator | front: IP43 (installed) rear: IP20 |
Protection class sensor | IP67 |
Influence of external magetic fields on the magnetic sensor | external magnetic fields > 1 mT, whicj directly impinge upon the sensor, can affect the system accuracy |
FLYER
OPERATION MANUAL
QUICK GUIDE FOR FDT SOFTWARE UPDATE TOOL